VIDEO:
30 SECOND
PART BUILDER
EXPLAINED
TQ, Tubing, 2-Layer Soft Fluoropolymer
SMC's 2-layer soft fluropolymer tubing, series TQ, has a special nylon resin outer layer and an inner layer of special fluropolymer. The internal smoothness of the TQ's inner layer is equivalent to Ra 0.02µm, and because the TQ is translucent it helps in identifying fluid color. Compared to SMC's TL series, flexibility has been improved by up to 55%, and the weight has been reduced by approximately 44%. The TQ is an excellent choice for use in automobile, semiconductor, food, medical and machine tool industries.
How to order
Bend the tube into a U shape
at a temperature of 68°F
(20nC). Fix one end and bend
the loop gradually at 100
mm/min. Measure 2R when
the tube breaks or is crushed.
TQ0425 20
Length per roll
Symbol
20
100
Length
20 m
100 m
Tubing designation
How to measure the
minimum bending radius
Fixed
end
Specifications
How to Order
Note 1) There may be plasticizer (white powder) deposits on the external surface of the tube. Please be careful when the
tube is used in clean rooms. Otherwise, the clean level may decrease.
Note 2) When solvent is used, make sure to test in the same environment as the actual operating environment, and
confirm that no problem will occur in the operating conditions. The standard value of the Applicable Fluid List
below is the reference value based on the test result performed under specific conditions.
The product can be physically affected by temperature, pressure, chemical density, etc, causing permeation or
swelling, and this may cause some problems.
Note 3) Perform periodic maintenance inspections. If leakage continues to occur after tightening, replace the tube with a
new one. (Refer to Maintenance in the Specific Product Precautions on page 2.)
When the tube rotates, perform a test to make sure no problem occur in the actual operating conditions.
When the product is used with motion for a long time, or at a high temperature, the tubes may have leakage due
to deterioration of the materials.
Note 4) Observe the lesser value of the maximum operating pressure between the tubing and fitting. The surge pressure
must not exceed the maximum operating pressure. If the surge pressure exceeds the maximum operating
pressure, it will result in damage to tubes and fittings. Furthermore, abnormal temperature rise caused by
adiabatic compression may result in the tube bursting.
Note 5) Minimum bend radius (refraction value) is not guaranteed. The value of 2R in the left figure is measured with a
bent or flattened tube.
Note 6) For the installation of fluoropolymer fitting LQ1 and LQ3, please contact SMC.
Insert fittings KF, KFG2, VCK series
Miniature fittings M, MS series (Hose nipple type)
Fluoropolymer fittings LQ1, LQ3 series
Note 6)
Designation
TQ0425
O.D. (mm)
I.D. (mm)
Roll
Color
Note 1)
Fluid
Note 2)
Fluid temperature (fixed usage)
Material
Max. operating
Note 4)
pressure psi (MPa)
Min. bending radius (refraction value) (mm)
Applicable fittings
Note 3)
20 m
100 m
68°F (20nC)
4
2.5
290 (2.0)
4
276 (1.9)
9
218 (1.5)
26
160 (1.1)
42
174 (1.2)
37
TQ0604
6
4
TQ0806
8
6
Translucent (Material color)
Air, Water, Inert gas, Solvent
Air, Inert gas: –4 to 212°F (–20 to 100nC), Water, Solvent: 32 to 158°F (0 to 70nC) (No freezing)
Inner layer: Special fluoropolymer, Outer layer: Special nylon resin
TQ1008
10
8
TQ1209
12
9
Temperature °F (nC)
–4 to 68 (–20 to 20)
86 (30)
104 (40)
122 (50)
144 (60)
158 (70)
158 (80)
194 (90)
212 (100)
TQ0425
290 (2.0)
247 (1.7)
203 (1.4)
174 (1.2)
160 (1.1)
145 (1.0)
131 (0.9)
116 (0.8)
102 (0.7)
TQ0604
276 (1.9)
232 (1.6)
203 (1.4)
160 (1.1)
145 (1.0)
131 (0.9)
116 (0.8)
102 (0.7)
87 (0.6)
TQ0806
218 (1.5)
174 (1.2)
145 (1.0)
116 (0.8)
102 (0.7)
87 (0.6)
73 (0.5)
58 (0.4)
58 (0.4)
TQ1008
160 (1.1)
131 (0.9)
116 (0.8)
87 (0.6)
73 (0.5)
58 (0.4)
58 (0.4)
44 (0.3)
44 (0.3)
TQ1209
174 (1.2)
145 (1.0)
131 (0.9)
116 (0.8)
102 (0.7)
87 (0.6)
73 (0.5)
58 (0.4)
44 (0.3)
Chemical
Hydrochloric acid
Sulfuric acid
Nitric acid
Caustic soda
Caustic potash
Ammonlum hydroxide
Hydrogen peroxide
Water
Phenol
Benzene
Toluene
Xylene
Carbon tetrachlorlde
Acetone
Methyl ethyl ketone
Inner layer
Special
fluoropolymer
Outer layer
Special
nylon resin
×
×
×
Chemical
Citric acid
Stearic acid
Formic acid
Ethyl acetate
Butyl acetate
Methyl alcohol
Ethyl alcohol
Butyl alcohol
Isopropyl alcohol
Cellosolve
Hexane
Cyclohexane
Mineral oil ASTM No.3
Naphtha
Inner layer
Special
fluoropolymer
Outer layer
Special
nylon resin
Max. Operating Pressure
Applicable Fluid List
Fluid in the list below are chemically inert
Note 1)
, to tubing material. Possible physical
effects
may occur such as penetration and swelling due to temperature, pressure and chemical
density. To use tubing in a solvent environment, tests should be performed with the same
environment to ensure no problem occurs with operating environment.
Note 1) “Chemically inert” means – not to cause any chemical reaction.
Note 2) Criteria: Applicable, Not recommended, × Inapplicable
Note 3) Applicable Fluid List shows the reference value based on test results performed under
specific conditions. Application for products is not guaranteed.
Note 4) Applicable Fluid List is for tube materials. For use in environments containing solvents,
please contact SMC.
Unit: psi (MPa)
RoHS
Note 5)
1
2-Layer Soft Fluoropolymer Tubing
Series TQ
Email Part
Email How to Order Page
Products
- Actuators
-
Directional Control Valves
- Directional Control Valves Overview
- Solenoid Valves - 4 & 5 Port
- Solenoid Valves - 3 Port
- Solenoid Valves - Direct Operated
- Industrial Communication
- Air Operated Valves
- Mechanical & Hand Operated Valves
- Safety Pressure Relief Valves
- Solenoid Valves - ISO
- Clean Room Products
- Valve Manifold Configurator
- Airline Equipment
- Air Dryers & Main Line Filters
- Connectors
- Vacuum Products
- Industrial Communication
- Sensors & Switches
- Fluid Process
- Static Control
- Electric Actuators
- Chillers
- Process Gas Equipment
- High Vacuum
- Chemical Handling Equipment
- Secondary Battery