EX600-W, SI Unit, Wireless

  • EX600-W, SI Unit, Wireless

The EX600 serial interface offers a full suite of diagnostics and programmable parameters to meet the most stringent requirements. The EX600 offers excellent flexibility including digital input, digital output and analog input unit options. With the use of D-sub output blocks, a maximum of 9 remote D-sub manifolds can be attached to one EX600 communication module. This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves. Available protocols include  Ethernet/IP™, PROFINET.  The EX600 wireless cannot be used in countries where wireless is not supported.  Refer to the catalog for details of countries where wireless is supported.

  • Fieldbus: EtherNet/IP™, PROFINET
  • Output Method: PNP, NPN
  • Number of I/O points: 1280 inputs/1280 outputs
  • Enclosure: IP40 & IP67 (Manifold Assembly)
  • Operating temp. range: -10 to +50°C
  • Standards: CE marking, RoHS compliant
  • Weight: 280g & 300g
Configuration Options
   
 
Compliance: ______
Copy Configuration Number

Product Options

Select Product Options
Select values from the drop down lists or make appropriate selections to configure the part number.
Type Configuration Status
SI Unit Configuration Status
Output Configuration Status
Options in:
  • Gray are not compatible with other selected option value.
  • Red conflict with another selected option value.
  • Amber are not recommended.