- FC2W, Flow Controller for Water, Pulse Output, 0.5-16 Lpm
FC2W, Flow Controller for Water, Pulse Output, 0.5-16 Lpm
FC2W is a flow controller for water between 0-50°C. A motor driven adjustable flow restriction works together with feedback from a Karman vortex flow sensor to respond to an analog input signal establishing the flow rate. When a single water supply source is divided into multiple lines, the flow rate between lines can be inconsistent. FC2W controllers can adjust flow on each line to a constant rate. FC2W does not include a flow shutoff feature. Pair the controller with a VXZ 2-port soleoid valve to stop flow for any reason. The device includes an error status LED. This is a grease-free product.
- Flow ranges (lpm): 0.5-4.0, 2.0-16.0
- Port sizes (Rc): 3/8, 1/2
- Operating pressure (MPa): 0.2-0.4
- Power supply: 24 VDC
- I/O signals: 1 to 5 VDC [IN] / variable frequency pulse [OUT]
- Accuracy: ±5%F.S.
- Response time: ≤10s
How to order
(Blue)
(Black) Output signal
(White) 1 to 5 V
(Brown)
24 VDC
Connector
q
w
e
r
Flow_SIG
GND
Vcc
Analog_IN
e
r
t
Output pulse frequency:
f = 1/t [Hz]
0 V
max. 24 VDC
Load
Blue
Black
*
Select a
load so that
the current
is 10 mA or
less.
Main circuit
500 ms500 ms
2000 ms
250 ms250 ms
Flow rate control
Position control
(Fully closed)
1.31.2
Input signal
Voltage [V]
4.0
4.2
5.0
0.4
Flow rate command value
[L/min]
0
1.0
Flow rate control
Position control
(Fully closed)
1.31.2
Input signal
Voltage [V]
16.0
16.8
5.0
1.6
Flow rate command value
[L/min]
0
1.0
Flow rate
[L/min]
4.0
720
Frequency: f
[Hz]
0.5
1040
Flow rate
[L/min]
16.0
703
Frequency: f
[Hz]
2.0
0 91
FC2W-X110
FC2W504 03 X110
How to Order
Piping port size
Symbol Port size
03
3/8
Piping port size
Symbol Port size
04
1/2
Lead wire
3
Lead wire with connector (3 m)
Flow rate control range
0.5 to 4.0 L/min
2.0 to 16.0 L/min
FC2W520 X110
Specifications
Input Signal — Flow Rate Characteristics
Output Signal Pulse Frequency — Flow Rate Characteristics
Model
FC2W504-03-3-X110 FC2W520-04-3-X110
Applicable fluid
Water
Flow rate detection method
Karman vortex
Flow rate control range
0.5 to 4.0 L/min 2.0 to 16.0 L/min
Flow rate measurement range
0.4 to 4.2 L/min 1.6 to 16.8 L/min
Operating pressure range
0.2 to 0.4 MPa (Fluid temperature: 0 to 50°C)
Withstand pressure
0.6 MPa
Operating temperature range/Fluid temperature range
0 to 50°C (No condensation)
Control accuracy
±5%F.S.
Temperature characteristics
±5%F.S. (0 to 50°C, 25°C reference)
Leakage when fully closed
*
1
0.4 L/min or less 1 L/min or less
Fully close function
Shutoff function not provided
Response time
*
2
10 s or less
Input signal
*
3
Analog voltage input: 1 to 5 VDC Input impedance: 1 MΩ
Output signal
*
3
Flow rate pulse output
LED indicator
When the power is ON (PWR: Green is ON) When an error is detected (ERR: Red is ON or flashing.)
*
4
Power supply voltage
24 VDC±10%
Current consumption
0.5 A
Main materials of parts in contact with fluid
PPS, PP, POM, FKM, Stainless steel 303, Stainless steel 304, SCS13 Non-grease specifications
Piping port size
03: Rc3/8 04: Rc1/2
Weight
515 g 530 g
*1
Use an external shutoff valve to stop the flow in an emergency.
Recommended 2 port solenoid valves
Series
Recommended 2 port
solenoid valves
Note
FC2W504
VXZ232D
N.C./Stainless steel/
Port size Rc3/8
FC2W520
VXZ242G
N.C./Stainless steel/
Port size Rc1/2
*2
Time taken until the flow rate reaches approximately 90% of the
set value relative to the flow rate command value (input signal).
*3
Refer to Graphs 1 and 2 for the relationship between the flow
rate and the I/O signals.
*4
The LED status when an error is detected is summarized in the
table below.
LED Status When an Error is Detected
Wiring Diagrams
Example of output signal wiring
FC2W504
(Graph 1)
Status LED status Action to be taken
EEPROM error
Stays lit.
Automatically recovered when reading
and writing are performed correctly.
Over
current
Flashing: Flashing cycle of 500 ms
Not automatically recovered.
Turn power off and then on
again.
Insufficient
supply flow
rate
Flashing: Two flashing cycles of 250 ms at two-second intervals
Error automatically resets
when the supply flow rate is
recovered (LED goes off).
FC2W504
FC2W520
(Graph 2)
FC2W520
3
304
1
A
Related Products
Email Part
Email How to Order Page
Products
- Actuators
-
Directional Control Valves
- Directional Control Valves Overview
- Solenoid Valves - 4 & 5 Port
- Solenoid Valves - 3 Port
- Solenoid Valves - Direct Operated
- Industrial Communication
- Air Operated Valves
- Mechanical & Hand Operated Valves
- Safety Pressure Relief Valves
- Solenoid Valves - ISO
- Clean Room Products
- Valve Manifold Configurator
- Airline Equipment
- Air Dryers & Main Line Filters
- Connectors
- Vacuum Products
- Industrial Communication
- Sensors & Switches
- Fluid Process
- Static Control
- Electric Actuators
- Chillers
- Process Gas Equipment
- High Vacuum
- Chemical Handling Equipment
- Secondary Battery